首页    美国GMW电磁铁    磁场测量

磁场测量

BDMetrolab_168_det-300x200

teslametar-2-1-300x168

Bartington-Mag01H-300x190

Mag-13MS100-300x166

Metrolab THM1176/TFM1186 USB Teslameter Senis 3MTS USB Teslameter Bartington Fluxgate Magnetometer, 1-axis Bartington Fluxgate Magnetometer, 3-Axis, Low Noise
The Metrolab THM1176 and TFM1186 are unique three-axis Magnetic Field Probes with USB Interface and power via the interface. The 3MTS is an easy-to-use handheld Teslameter/Gaussmeter to measure all 3 magnetic field components simultaneously within a very small a volume. This standalone single axis fluxgate magnetometer is a portable, high-performance instrument. It provides measurement and display of the intensity of static and slowly varying magnetic fields in the direction of the probe. Bartington 3-Axis Fluxgate Sensors are compact, high performance fluxgate sensors with integral electronics that provide precision measurements of static and alternating magnetic fields in three axes.
•TFM1186: 100uT range
•THM1176-LF: 8mT range
•THM1176-MF: ±0.1, 0.3, 1, 3T range (manual or auto-select)
•THM1176-HF: ±0.1, 0.3, 1, 3T, 20T range (manual or auto-select)
•3-axis Hall probe
•Measurement ranges: 100mT, 500mT, 3T, 20T
•Measurement accuracy:<1% (100mT, 500mT), <3% (3T)
•Bandwidth: DC – 500Hz
•Range from 0.1nT to 2mT
•Axial and Transverse Probes
•Cryogenic Probes
•High-vacuum Probes
•Range: ±70, ±100, ±250, ±500, or ±1,000µT
•Output: ±10V Full Scale
•Bandwidth: DC to 3kHz
•Noise: 6 to 10pTrms/√Hz at 1Hz

Mag610-L-300x194

MAG649-2-300x300

Spacemag-Lite

Transducers-cut-300x170

Bartington Fluxgate Magnetometer, 3-axis, High Temp Bartington Fluxgate Sensors, 3-axis, Miniature and Low Power Bartington Fluxgate Magnetometer, 3-axis, Space Senis Magnetic Field Transducer, 1-Axis
High temperature fluxgate probes for operation to 175° C or 215° C. Bartington Fluxgate Magnetomers with lower power, smaller size, wide bandwidth or lower cost for applications such as probe arrays. Spacemag-Lite is a compact three-axis fluxgate magnetometer for spaceflight applications. Built from commercial off the shelf components to control cost in CubeSat applications. Senis Magnetic Field Transducer, 1-axis
•Directional drilling.
•Measurement while drilling (MWD).
•Borehole tool attitude monitoring.
•Low Power: Mag648/648
•Miniature Size: Mag612
•Wide Bandwidth: Mag639
•Lower Cost: Mag670/Mag690
•Conforms with ‘Pumpkin’ CubeSat PCB specifications
•Vacuum compatible
•Noise: ≤ 20pTrms/√Hz at 1Hz
•Probe-only and PCB schematics version available
•I1A Integrated Hall probe for very low noise measurements
•F1A Fully-Integrated Hall probe for very high spatial resolution
•Range: ±20mT … ±20T
•Bandwidth: 2.5kHz

Transducers-cut-300x170

D133DS-F-ED1-2x2-300x240

D151PG-R-ED1-2x2-300x214

BDMetrolab_101_det-300x200

Senis Magnetic Field Transducer, 3-Axis Group3 Digital Teslameter, 1-axis, DTM-133 Group3 Digital Teslameter, 1-axis, DTM-151 Metrolab Digital NMR Teslameter, PT2025
Senis Magnetic Field Transducer, 3-axis The Group3 DTM-133 is a high performance Hall effect teslameter (gaussmeter) with digital linearity correction to provide 0.03% accuracy, resolution to 100ppm, and a temperature stability of 100ppm/°C. The Group3 DTM-151 is the highest performance Hall effect teslameter (gaussmeter) commercially available with digital linearity and temperature correction to provide 0.01% accuracy. The Metrolab PT2025 Teslameter (Gaussmeter) utilizes the nuclear magnetic resonance (NMR) of protons or deuterons in a magnetic field. It achieves 5ppm absolute accuracy and 0.1µT (1mG) resolution for measurement or mapping of uniform magnetic fields in the range 0.043T (430G) to 13.7T (137kG). Optional Probe Multiplexers enable readout of up to 64 Probes.
•F3A Fully-Integrated Hall probe for very high spatial resolution
•Range: ±20mT … ±20T
•Bandwidth: 25kHz
The DTM-133 digital Hall teslameters (gaussmeters) provide superior accuracy, resolution, and long term measurement stability. The Group3 DTM digital Hall teslameters (gaussmeters) provide superior accuracy, resolution, and long term measurement stability. •PT2025 has been replaced by PT2026. See PT2026 for all new systems.

BDMetrolab_086_det-300x200

MFC2046-System-300x200

BDMetrolab_141_det-200x300

BDMetrolab_163_det-300x200

Metrolab Digital NMR Teslameter, PT2026 Metrolab Magnetic Field Camera, MFC2046 Metrolab Magnetic Field Camera, MFC3045 Metrolab Fast Digital Integrator, FDI2056
The Metrolab PT2026 Teslameter (Gaussmeter) utilized the nuclear magnetic resonance (NMR) of protons or deuterons in a magnetic field. Combined with Pulsed Wave (PW) NMR detector and advanced signal processing, it provides significant performance improvements over the previous generation Metrolab PT2025 Teslameter (Gaussmeter). The Metrolab MFC2046 Magnetic Field Camera utilizes a proton NMR sensor Array to simultaneously measure up to 32 field points with better than 5ppm absolute accuracy and 0.1ppm relative accuracy in 0.5 to 2 seconds. The very high resolution and stability of the MFC also enable measurement of magnet stability and noise effects. The Metrolab MFC3045 Magnetic Field Camera, utilizes a proton NMR sensor Array to simultaneously measure up to 32 field points with better than 5ppm absolute accuracy and 0.1ppm relative accuracy in 0.5 to 2 seconds. Leading MRI Magnet and System manufactures have adopted the MFC3045 to provide a ten times improvement in mapping resolution and a ten times reduction in aqusition period. The Metrolab FDI2056 Fast Digital Integrator is a high precision, high speed voltage integrator. Combined with an appropriate flux coil, it makes an extroidinarily fast, flexible and sensitive magnetometer.
      •Flexible: Wide range of inputs, to ±20V max
•Fast: 500 kS/s
•Precise: 18 bit resolution
•Real-Time Data Acquisition

Senis-NVM-Front-300x242

     
Senis NVM-01 NanoVolt Amplifier      
The NVM-01 is a low noise amplifier module, for sensitive DC/AC measurement and data acquisition systems. It is ideal as an input for accurate voltage measuring systems down to nV range and for measuring of low noise and of low impedance sources.      
•Ultra-low noise & offset fluctuation amplifier, allowing very high resolution measurements (spectral density of noise down to 1 nT/ Hz )
•Very high linearity